Scroll down

Planning underfloor heating for a house or apartment in the Netherlands? Learn how water-based and electric systems differ, which installation methods work during a renovation, and what to consider when choosing insulation, controls and flooring. This guide also explains what ZHH needs to prepare a tailored quotation.

Animation showing heated water circulating through underfloor heating pipes and distributing warmth throughout a room.

Contact us directly

Do you have questions about a renovation, bathroom, roofing, electrical work or other building work? Message us on WhatsApp or give us a call.

Phone / WhatsApp: 06 4250 3008

Underfloor heating and renovation services by ZHH in the Netherlands

ZHH Zaag Hamer Huis B.V. provides renovation and installation services in the Netherlands. Underfloor heating plans must consider the current floor, insulation, existing central heating and intended floor covering together before the scope of work is agreed.

When upgrading a house or apartment, the floor build-up, connection to the heat source, bathroom requirements and related renovation tasks should be assessed together. Installation options and timescales depend on a survey and the building’s actual conditions.

Contact ZHH in English, Dutch or Polish. Include the town or city in the Netherlands, approximate floor area, type of property and photos of the existing floor for an initial assessment.

How does underfloor heating work?

Underfloor heating distributes warmth over a large floor area. Water-based systems circulate heated water through pipes, while electric systems use heating mats or cables. Comfort and efficiency depend on insulation, flow temperature, floor covering, system design and controls. The right solution depends on the building and its existing floor.

Read moreCollapse article

From the heat source to the floor surface

In a water-based system, heated water circulates through pipe loops embedded in the floor. Heat travels through the floor layers into the room. Electric systems use powered cables or heating mats.

A well-designed large heating surface can provide comfort at a lower surface temperature than small radiators. A heat-loss calculation is still needed to confirm that each room can reach its required temperature.

What affects comfort?

Floor insulation, supply-water temperature, pipe spacing, floor finishes and correctly configured controls all matter. Thick layers with high thermal resistance can slow heat transfer.

  • Balanced design and commissioning help maintain even room temperatures.
  • Some floor systems respond slowly to thermostat changes because they store heat.
  • Check the condition of the subfloor and heating requirements before choosing a system.

Water-based or electric underfloor heating?

Water-based underfloor heating often suits larger floor areas and can work with a heat pump or an appropriately designed boiler system. Electric heating may be practical for a small renovation, such as a single bathroom. Compare installation requirements, the heating demand and expected running costs rather than upfront cost alone.

Read moreCollapse article

When is a water-based system suitable?

Water-based underfloor heating is frequently chosen for whole homes and larger renovations. It may be connected to a heat pump or another compatible heat source.

Allow space for the manifold, connecting pipes, floor construction and separate temperature zones.

When can an electric system make sense?

Electric heating mats can be practical in a small area such as a bathroom being retiled. No water manifold is needed, but electrical loading, protective devices and expected energy consumption must be assessed.

What should you compare?

  • Total floor area and calculated heat demand.
  • Available installation depth and amount of renovation work.
  • Purchase, installation, maintenance and energy costs.
  • Control options and compatibility with the existing heating system.

What components does a water-based system need?

A typical installation includes heating pipe loops, fixings, floor and edge insulation, a manifold, connection to the heat source, temperature controls and a compatible floor structure. Depending on the design, additional pumps, mixing controls or zone actuators may be required. The exact components must match the property and system.

Read moreCollapse article

Floor layers and heating circuits

Pipe loops are secured to an appropriate base or system boards. Insulation beneath the pipes reduces downward heat loss; edge strips and expansion joints allow movement in the floor.

Pipe diameter, spacing and circuit length should be chosen according to heat load and the selected system requirements.

Manifold, valves and balancing

The manifold connects individual circuits and enables flow adjustment. Depending on the system, valves, actuators, air vents, mixing controls and a pump may be required.

Thermostats and zoning must work with the heat source and floor design. Installing a thermostat alone does not replace hydraulic balancing.

Records and accessibility

  • Keep pipe layout drawings and photographs taken before the floor is covered.
  • Ensure the manifold and serviceable components remain accessible.
  • Use compatible components in line with manufacturer instructions.

Which installation methods are available?

In a wet system, the pipes are covered with a suitable screed. Dry systems use prefabricated boards and heat-spreading layers, reducing wet construction work. Low-profile systems can suit some renovations. The choice depends on structural loading, available floor depth, acoustic requirements and the condition of the existing subfloor.

Read moreCollapse article

Wet screed installation

Heating pipes are incorporated into a suitable screed. This can store heat effectively, but requires appropriate construction and drying time.

Check permitted floor loads, screed depth, movement joints and the screed manufacturer’s requirements.

Dry systems and low-profile options

Dry systems use prefabricated boards and heat-spreading layers. Low-profile products may suit renovations with limited available floor height.

Not every method works with every finish. Structural weight, acoustic performance and compatibility must be considered.

How to choose an installation method

  • Assess the type and load-bearing capacity of the existing subfloor.
  • Measure thresholds, doors and the available depth for added floor layers.
  • Include insulation, final flooring and the planned heat source in the decision.

Can underfloor heating be milled into an existing floor?

Floor milling creates channels in a suitable existing screed for the heating pipes. Not every screed can be milled: its type, thickness, condition, concealed services and structural restrictions must be checked first. Milling can limit the additional floor height, but does not remove the need to assess insulation and heat loss.

Read moreCollapse article

How does floor milling work?

A specialist machine cuts channels into a suitable existing screed. After cleaning, pipes are inserted and covered in line with the system instructions.

Milling may keep added floor height low, but it is unsuitable for some floor constructions.

When should milling be avoided?

Screeds that are too thin, damaged or otherwise unsuitable, hidden services, structural limitations or inadequate insulation can make milling unsafe or impractical. The floor construction must be investigated beforehand.

Checks before milling

  • Identify the screed type, thickness, condition and any hidden pipes or cables.
  • Confirm that the required heating output is achievable.
  • Review flooring requirements and permitted temperatures.
  • Plan how pipe circuits will connect to the manifold.

System design: heating zones, pipe spacing and output

Correct sizing starts with a room-by-room heat-loss calculation. The design sets pipe spacing, circuit lengths, operating temperatures, hydraulic resistance, expansion joints and control zones. There is no universal pipe spacing for every room; it depends on the heat source, floor construction and required heating output.

Read moreCollapse article

Calculate heat loss first

Design should start with a heat-loss assessment for every room. Insulation, windows, ventilation and design temperatures all affect the result. Only then can the required floor heat output be determined.

Pipe spacing, circuit lengths and zones

Pipe spacing and circuit length influence temperature distribution and flow resistance. One standard spacing should not be assumed for every room. Bathrooms, living spaces and bedrooms can require different controls and layouts.

Balancing and design documentation

  • Manifold position and routing of individual heating circuits.
  • Heat-source specifications, working temperatures and flow rates.
  • Zone layout, thermostats and corresponding controls.
  • Movement joints and restrictions around fixed furniture or fittings.

Installing underfloor heating step by step

The project starts with a site assessment and preparation of the subfloor. Insulation or system boards are then installed, followed by heating pipes or mats and the required connections. Water-based systems must be pressure-tested in accordance with the system instructions before they are covered. Screed, floor finishes, balancing and commissioning follow the relevant product requirements.

Read moreCollapse article

1. Survey and subfloor preparation

Before installation, assess the scope of work, condition and height of the existing floor and insulation options. Prepare the surface according to the selected system requirements.

2. Installation and connections

Install system boards or insulation, pipework or mats, the manifold and required connections. The pipe layout should match the agreed design.

Before covering the pipework, carry out and record the prescribed pressure test. Electric installations require appropriate measurement and inspection by a qualified professional.

3. Screed, start-up and handover

Observe drying periods and the prescribed gradual heating procedure after the floor is laid. Balance and test all circuits, then provide the relevant installation records at handover.

Heat pumps and other heat sources

Low-temperature underfloor heating often works well with a heat pump because a large surface can deliver warmth at a relatively low water temperature. Actual efficiency depends on insulation, calculated heat demand, system sizing and controls. Compatibility of the full heating installation should be checked as part of a renovation.

Read moreCollapse article

Why does underfloor heating suit heat pumps?

A large heated floor area can keep rooms comfortable using relatively low water temperatures. This can improve the performance of many heat pumps, provided the property and system are properly designed.

Upgrading an existing heating system

When changing the heat source, assess existing equipment, insulation, heat demand and achievable operating temperatures. A mix of radiators and underfloor heating may need separate circuits and adapted controls.

Questions for the installer

  • Can underfloor heating meet the calculated heat demand in every room?
  • What flow and return temperatures are planned?
  • How will system controls, balancing and commissioning be handled?

Tiles, vinyl, laminate and timber flooring

The finished flooring affects heat transfer and permitted operating temperatures. Tiles and natural stone are often suitable. For vinyl, laminate and wood, always check the manufacturer’s underfloor-heating approval, thermal resistance, subfloor moisture limits and maximum surface temperature. Suitable underlays and adhesives are also important.

Read moreCollapse article

Tiles and natural stone

Ceramic tiles and natural stone usually transfer heat well. Use adhesives, grout and movement-joint arrangements suitable for a heated floor.

Vinyl, laminate and timber

For vinyl, laminate or timber, check the flooring manufacturer’s approval for the specific heating system. Consider the thermal resistance of all layers, subfloor moisture and maximum surface temperature.

An unsuitable underlay or excessive temperature can reduce performance or damage the flooring.

Checks before the final finish

  • Measure screed moisture in accordance with material requirements.
  • Confirm compatibility of adhesives, underlay and finished flooring.
  • Follow the prescribed heating procedure and control temperatures correctly.

How much does underfloor heating cost in the Netherlands?

Cost depends on floor area, system type, existing subfloor, installation method, number of heating circuits, controls, heat source and floor reinstatement. Running costs depend on insulation, system efficiency and usage. A reliable quotation requires a clear scope of work. Include the approximate floor area, location, subfloor details and photographs in your enquiry.

Read moreCollapse article

What determines the installation price?

Floor area alone does not determine the quotation. System selection, access, removal of existing layers, insulation, installation method, connections and controls all affect price.

Milling into a sound existing screed is different from rebuilding the full floor. Comparing only prices per square metre may therefore be misleading.

Running costs

Energy use depends on the home’s heat demand, energy tariffs, heat-source efficiency and operating habits. Accurate predictions require this information.

How to request comparable quotations

  • Include the floor area, room types and property location in the Netherlands.
  • Describe the current floor, heating system and preferred finish.
  • Ask whether insulation, connections, balancing and floor reinstatement are included.

Common mistakes to avoid

Problems can arise from insufficient insulation, poorly arranged heating zones, excessive temperatures, missing checks before covering pipes, incorrect movement joints or incompatible flooring. Repairs after the floor has been finished can be expensive. Proper inspection, testing and documentation matter throughout the installation.

Read moreCollapse article

Mistakes before work begins

Without a heat-loss calculation and insulation assessment, the system may provide insufficient warmth. Poor zoning or inadequate manifold space can also cause problems.

Installation mistakes

Damaged pipes, incorrect movement joints, skipped pressure testing and incompatible materials are serious risks. Repairs after completion can require opening the finished floor.

Mistakes during use

  • Operating above the flooring manufacturer’s maximum temperature.
  • Incorrect thermostat settings or heating circuits that have not been balanced.
  • Drilling into the floor without consulting the pipe layout.

Request an underfloor heating quotation from ZHH

Tell us whether the work is for a house, apartment or individual room. Include the estimated floor area, location in the Netherlands, intended heat source and the type and condition of the existing floor. Photos are helpful. Explain whether removal, insulation and final floor finishes are part of the project so that ZHH can assess the work.

Read moreCollapse article

Property and room details

Tell us the location, approximate floor area, property type and whether this is a new installation, replacement or renovation. A basic floor plan and photographs can be useful.

Existing floor and heat source

Describe the existing screed, tiles and other layers and whether these must be removed. State the current heating source and whether you are considering a heat pump. If the floor build-up is unknown, please say so.

What to include in your enquiry

  • Photos of rooms, thresholds and the existing floor.
  • Approximate floor area and preferred project timing.
  • Information on final flooring and any other renovation work.
  • Specific questions about milling, costs or system selection.

Frequently asked questions about underfloor heating

Can underfloor heating be installed in an older house?

Often yes, but insulation, floor depth and condition, heat source and heating demand must be checked. Additional renovation work may be needed.

Can underfloor heating be milled into every screed?

No. The screed must be suitable in type, thickness and condition, and existing services must be located before milling.

Which is better: water-based or electric underfloor heating?

It depends on floor area, available energy source, usage and the renovation. Electric systems can be useful in small zones; water-based systems often suit larger areas.

Does underfloor heating work with a heat pump?

It is often a good combination when correctly designed for low supply temperatures. The property’s heat loss and system specifications must be checked.

Can I install vinyl or laminate over underfloor heating?

Yes, provided the specific flooring, underlay and installation method are approved by the manufacturer for the heating system.

How long does underfloor heating installation take?

The time depends on floor area, installation method, preparation and the drying time of any new screed. A schedule can be confirmed after assessing the site.

How much does underfloor heating installation cost in the Netherlands?

A price depends on a quotation for the specific work. Subfloor condition, floor area, manifold, controls and finishes are among the main factors.

Can underfloor heating replace radiators entirely?

It can if the calculated heating output meets the heat demand of every room. This cannot be confirmed without a proper system design and property assessment.

Request a renovation quote

Complete this short form and we will contact you to discuss scheduling and a quotation.

You do not need to know every detail yet. Enter the basics and we can discuss the rest by phone or WhatsApp.

You can contact us in English, Dutch or Polish.

1. Contact details
1. Contact details
2. Work location
2. Work location
3. Which services do you need a quote for? (select all that apply)
4. Current condition
4. Current condition
The property is:
Has the property been renovated before?
5. Floor area / scope
5. Floor area / scope
6. Timing and urgency
6. Timing and urgency
Is this urgent?
7. Photos (optional)

You can attach up to five photos. Another upload field will appear when you choose a file.

8. Additional details
8. Additional details
9. Preferred survey time (optional)
10. How did you hear about us? (optional)
11. Consent
11. Consent
Outline of a house
78 m²